Aculon HB | Hydrophilic Treatment

Harmonization Code : 34021900 | Surface active agents

Aculon HB | Hydrophilic based

Main features

  • Used as provided for wipe applications
  • Use for dip treatment applications
  • Gentle enough for many substrates.

Product Description

Aculon's HB  is a water-based specialty coating capable of supplying hydrophilic properties across a broad spectrum of metal or glass surfaces. It is quick and easy to apply and in some cases may also be used on plastics.

Aculon HB: Aculon HB is a water-based coating product that imparts hydrophilic functionality to multiple substrate types. 

Product Family

AHB

Catalog Product

Unlike other products we offer, the products listed on this page cannot currently be ordered directly from the website.

Packaging
Please select before adding your product to your cart.
TDS, SDS & Technical Documents
  • Aculon HB use instructions
    English (Technical documents)
  • Aculon HB TDS
    English (Technical Data Sheet (TDS))
  • Aculon HB SDS
    English (Safety Data Sheet (SDS))

Technical Specifications

General Properties
Specific Gravity Specific Gravity
1.1

Additional Information

 

How to apply the Aculon HB

STEP 1  CLEAN

STEP 2  TREAT

STEP 3  DRY

 

Parts must be sufficiently clean before treatment for proper bonding and effective application.

To clean, solvents or soap and water can be used to degrease the substrate.

Then, a cleaner is recommended to remove monolayer-scale contaminants.

 

 

Wipe - With the wipe, thoroughly apply pressure to the location where the hydrophilic properties are required

This product does not require a cure, however, in some cases and substrates a brief 5-minute cure at 60⁰C will benefit. 

Dip - Fully immerse the part in the treatment solution for 1 minute, then remove the substrate.

 

Application Tips

  • If any bath will be subject to environmental contamination, recirculate the solution through a 0.2-micron polypropylene media filter.
  • Dip tanks should be made of polypropylene or PTFE polymers.
  • The product should be used at room temperature.
  • Coat the substrate as soon as possible after cleaning to prevent recontamination.
  • This material may be reapplied as needed.
  • Dry temperatures and conditions should be optimized based on substrate and durability requirements.

 

 

Recently viewed products

Leading Brands Trust in Our Products and Services

Products that Perform | Knowledge that Serves | Service that Delivers